BRAND | ARDETEM |
Product | TAI60-A5702000145 |
Description | TRANSMITTER |
Internal code | ONR4786267 |
Technical specification | POWER SUPPLY MEASUREMENT TRANSMITTER UNIVERSAL version in new casing replacing the TAI60 A True rms measurement Input U: 100/190/440/600 V AC Input I: 1 A and 5 A AC Cycle time 40 ms Measurement: U, I, F. 1 mA isolated analog output Galvanic isolation: I/O/ALIM. : 3kV Universal power supply 20 to 250 vac and 21.5 to 250 vdc DIN rail fixing. |
Discover the superior quality and performance of the ARDETEM TAI60-A5702000145 with Onrion LLC in Argentina . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The TAI60-A5702000145 is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of TAI60-A5702000145 :
At Onrion LLC , we offer the TAI60-A5702000145 at competitive prices and with the fastest delivery times across Argentina . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Onrion LLC ?
Get Your Quote Today! Ready to enhance your operations with the TAI60-A5702000145 ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply ARDETEM products, Onrion LLC is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Display / Detachable programming unit for all Ardetem devices
DRB-5 TPI DIN rail holder Connecting terminal / connector for Hat rail for the power supply and bus for two devices, a connector is required
Three-phase universal analyzer Disturbancen Three-phase universal analyzer interference 3 or 4 wire three-phase systems, reading out balanced and unbalanced networks 2 R-2 relay outputs NO F - Modbus TCP Ethernet output Display: 96 x 96 backlit Display up to 50 parameters Upper and lower wave analysis 2 programmable voltage ranges Un = 100V LN / 173V LL and 330V LN / 600V LL 2 programmable current areas A 0..1 and 0..5 A Universal power supply AC / DC Reaction time 40 ms (2 cycles) Standard output RS 485 Modbus Customs tariff number: 9030390090 Country of origin: France / EU
TPIs 50 N F / I converter Ethernet single-channel frequency converter Input: contact, logic, Namur, NPN / PNP Analog output: 0 - 20 mA, 0 - 10 V PC programmable with software SUPERVISION via USB port or Ethernet
TPIs 12 transmitters with process input 1 analog output Transmitters with process input in 7.2 mm-housing Input: mA; mV; V 1 Analog output: 0 - 10 V; 0/4 - 20 mA active Power: 24 VDC PC programmable with software SUPERVISION via USB port
Universal phase analyzer Disturbancen AC universal analyzer for interference 3 or 4 wire three-phase systems, reading balanced and unbalanced networks 2 R-2 relay outputs NO F - Modbus TCP Ethernet output Display: 96 x 96 with backlight Display up to 50 parameters Upper and lower wave analysis 2 programmable voltage ranges Un = 100V LN / LN 173V LL and 330V / 600V LL 2 programmable current ranges 0 to 1 A and 0 .5 A Universal Power Supply AC / DC 40ms response time (2 periods) Standard output RS 485 Modbus Customs tariff number: 9030390090 Country of origin: France / EU
TRM4 2A Universal three-phase analyzerUniversal three-phase analyzer3 or 4 wire three-phase systems, readingbalanced and unbalanced networksInput: Voltage 0 3 .150 VAC, 0 ... 500 VACOutput: 3 Current 0 .1 0 .5 A and A (automaticswitching)Universal power supply AC / DCResponse time 40ms (two periods)Outputs 2 x analog bipolar)PC programmable with software SUPERVISIONPossible options:Up to 5 programmable analog0 ... 20mA, 4 ... 20mA, 0 ... 5 mA two of thesebipolar)4 output relays without analog output, or 2Relay outputs with max. 2 analog outputsEthernetProfibus DP• Overload: 10 times the rated current for 10 seconds• 50 times rated current (EDF standard) for 60 ms
Display with bi-directional Process input, analog output + 2 relays Digital display 48 x 96mm, 4 digits bidirectional process input (mA, mV, V) mA output active and 2 relays Universal power supply 24 - 240VAC / DC via front panel or by means of PC and software SUPERVISION
Display 48 x 96mm with Universal Input + 2 relays in the output Digital display 48 x 96mm, 4 digits Universal input mA, V, temp. Potentiometer resistance 2 relays in the output Universal power supply 24 - 240VAC / DC via front panel or by means of PC and software SUPERVISION
Supervision programming tool Software to program the ARDETEM Devices including USB interface and connection cables
μCONSOLE LCD Display / Removable programming unit for all Ardetem devices
TPI 10 AR universal transmitter with Analog output and 2 relays TPI 10 AR Universal Input: current, voltage, temperature resistance Output: Analog (current / voltage), 2 relays Programmable with display / PC Universal power supply: 20-300 VDC / VAC
DIP400 with tropicalization option.
digital indicator universal power supply
electrical network analyzer
ELECTRICAL MEASURE CENTRAL Current input: 1A and 5 A AC Voltage input: 175 V and 600 V AC For all network types Graphical LCD with rear-lighting 28 measurable parameters: 3U, 3V, 3I, cos, f, F, P, Q, S, E... Display of the energies on 8 digits on a single line with automatic switching to the upper unit Automatic correction of the wiring Output: RS 485 Modbus/Jbus Universal power supply; 20 to 270 vac and 20 to 300 vdc Format: 96x96mm
Measurement of DC signals - Dimensions 96x96x108mm -LCD ,DC networks
Signal analyzer for electrical networks
INSULATION FAULT DETECTOR
programmable transmitter
AC MEASURE TRANSMITTERS - high insulation 4KV. Input 0-5A and standard output 4-20mA Galvanic partition: 4Kv Accuracy rating: <0.3% Power supply: 20 to 270 Vac and 20 to 300 Vdc
DC MEASURE TRANSDUCER / DC CONVERTER Input / input: 0-1000 VDC Output / output: 4-20 mA Galvanic partition / galvanic isolation: 2KV Accuracy rating / accuracy: 0.2% For DIN rail mounting / for DIN rail mounting Power supply / power supply: 20 ... 270 Vac and 20 ... 300 Vdc
TMP-HI-2 EXCITATION CURRENT TRANSDUCER ,I/P : 75A/100mV O/P : 4-20 mA AUX : 90-270 VAC, 88-350 VDC 2-WIRE SENSOR
Universal current and voltage transmitter
TPA-TRM-3-2A-3 - OBSOLETE, REPLACEMENT 20182 TRM4 2A
PROGRAMMABLE TRANSMITTER
TPI 302 SERIAL:0302-388- OBSOLETE, REPLACED BY TPI400
power converter
PROGRAMMABLE CONVERTER Input: mA,mV,V. Bidirectionnal current and voltage input up to +/- 300 V dc Accuracy rating: 0.1% Programmable scale factor Supply for 2-wire sensor Insulated analog output (voltage or current) For DIN rail mounting Programmable by software or µconsole (optional) Universal power supply: 20 to 270 vac and 20 to 300 vdc
A three-phase analyzer for synchronous networks Three-phase analyzer for synchronous networks DIN-rail mounting AC indicator for exchange or Three-phase systems Voltage input 0 1 .150 VAC, 0 ... 600 VAC + 20% 1 Current input 0 .1 0 .5 A or A (automatic switching) Spanungsversorgung Universal AC / DC Response time 40ms (two periods) 1 analogue output Programmable with Display (LCD μCONSOLE) or PC