BRAND | Stahl |
Product | 8146/5071-0TO15/70A |
Description | CONTROL UNIT |
Internal code | ONR4785570 |
Technical specification | WO/NT No: 30346550 0030 1750 Switches, Low voltage, Hazardous areas Type CONTROL UNIT Voltage, rated 400 V Current, rated 16 A Classification, hazard areas EX II 2 G EX DB EB IIC T6 GB Ex II 2 D Ex tb IIIC T80°C Db Ex II 2 G Ex db eb IIC T6 Gb IECEx PTB 06.0090 PTB 01 ATEX 1024 Ingress protection IP 66 Mat, housing POLYESTER RESIN GLASS FIBREREINFORCED Series 8146/5071 Temperature range, ambient -20 TO +40°C Connection cross-section 2.5 mmІ Mat, labels ADHESIVE LABEL Frequency 50/60 Hz Scale range 0 TO 15/70A Additional information: rotary actuator 38mm 3-digit ( t/r/t ) 1 x padlock. A3 Selector switch spring return 1 pc Lockable in OFF Contact element NC+NO Ammeter ct connection 1 pc Ammeter 72 x 72 mm 5A Ue, 2 times Bezel 72 x 72 for measuring instrument Earth terminal USLKG 5 1 pc Line-up terminal UT 2.5 10 pcs Side bottom brass plate 1 pc Side bottom 2 pcs Plant identification label, stainless steel 55 x 20 mm, screwed 1 pc Control box C/W stainless steel 316 mounting plate LG 170 x WD 50 x THK 6 mm and stainless steel bolt, nut, spring washer and flat washer |
Please Contact Us to Order to offer competitive prices and delivery time for Stahl - 8146/5071-0TO15/70A CONTROL UNIT number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Argentina Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
(Rotary handle, small lockable explosion-protected Enclosure material : Polyamide Seal : Standard Mounting : with threaded Switching function : latching Number of switching positions : 2 Construction type : vertical Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -50 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 For further information, see : www.r-stahl.com Web code 8082A)
8703-PUSH BUTTON ASSEMBLY (OBSOLETE REPLACED BY 8602)
PUSH BUTTON FOR START-NO CONTACT
Single-channel safety barriers explosion-protected
9118/11-11-10 - OBSOLETE (REPLACED BY 9118/11-11-10)
ics modul-mA isolating repeater(max vol.:8.7 V max. cur.:0.4 mA max. pow.:11mW power supp.:24 vDC)
Barrier
mA-Trennübertrager
iSPAC separation transformer
Isolator analog output
BARRIER: PROTECTIVE, for receiving and transmitting UNIFIED SIGNALs
(ISpac Switching amplifier Field Circuit Ex i explosion-protected Type : 9170/10-12-21s Max. Voltage Uo : 10,6 V Max. Current Io : 24 mA Max. Demand Po : 64 mW Min. nominal voltage : 120 V Max. nominal voltage : 230 V Nominal current : 12 mA Number of channels : 1 Output / channel : 1 change over contact LFD relay : Yes Line fault transparency : No Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Gas explosion protection : II (1) G [Ex ia] IIC Dust explosion protection : II (1) D [Ex ia] IIIC)
160293, IS PACIsolating RepeaterSwitching RepeaterField Circuit Ex iexplosion-protectedType : 9170/20-12-11sMax. Voltage Uo : 10,6 VMax. Current Io : 48 mAMax. Demand Po : 128 mWNominal voltage : 24 V DCNominal current : 33 mA Number of channels : 2Output / channel : 1 change over contactLFD relay : YesLine fault transparency : NoMin. ambient temperature : -20 °CMax. ambient temperature : +70 °CDust explosion protection : II (1) D [Ex ia] IIICFor further information, see : www.r-stahl.com Web code 9170ASwitching Repeater Series 9170, Field Circuit Ex i, dual channelBasic function: binary / digital inputIntrinsically safe input: [Ex ia] IICPower supply: 24 V DCInput: acc. to EN 60947-5-6 (NAMUR)Output / channel: 1 change-over contactConnection type: Screw terminals
(Binary output loop-powered IS pac)
(ISpac Isolating Repeater Temperature Transmitter Field Circuit Ex i explosion-protected Max. Voltage Uo : 6,5 V Max. Current Io : 19,7 mA Max. Demand Po : 32 mW Nominal voltage : 24 V DC Nominal current : 70 mA Number of channels : 1 Output : 0/4 ... 20 mA active / source Limit value contact (per ch.) : without Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Application range (Zone) : 2 Gas explosion protection : II 3 (1) G Ex nAc nCc [ia] IIC T4 Dust explosion protection : II (1) D [Ex ia] IIIC)
FIELDBUS ISOLATING REPEATER
(ISpac pac-Bus single element explosion-protected Nominal voltage : 24 V DC Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C)
p/n:162201; Type: 9440/15-01-11-C1243
Remote I/O IS1
P/N: 168660, Type: 9460/12-08-11
Analog input module
P/N: 168668, Type: 9465/12-08-11
Analog output module
Remote I/O IS1+ Analog Output Module HART explosion-protected
Remote I/O IS1Digital Output Moduleexplosion-protectedType : 9475/12-04-21Version : 4 channelsApplication range (Zone) : 1 , 2 , 21 , 22Max. Voltage Uo (Ex ia) : 26,2 VMax. Voltage Uo (Ex ib) : 26,2 VMax. Current Io (Ex ia) : 110 mAMax. Current Io (Ex ib) : 60 mAMax. Demand Po (Ex ia) : 722 mWMax. Demand Po (Ex ib) : 722 mWMin. ambient temperature : -20 °CMax. ambient temperature : +65 °CCCT No.: 85363010 CNNet weigth: 0,275 KG
P/N: 168688, Type: 9475/12-08-61
Remote I/O IS1
Remote I/O IS1+ Digital Output Module explosion-protected
I.S.1 8DO MODULE
Remote I/O IS1+Temperature Input Moduleexplosion-protected
INTERIOR REPAIR KIT COMPLETE